306
No Abbr.
Parameter function and description
Mode Default Range Unit
PC44 CACT
(■)
Capture: activate control:
u z y x
x(HEX):
activate Capture
x.bit3 x.bit2 x.bit1 x.bit0
x.Bit0 =
1
Start capturing; after capturing is complete, this bit
is set to 0 automatically.
PC43>0, the capturing data quantity decrease to
0. Capture is complete, DO: CAP_OK(ON)
PC43=0:
CAP
function
is
disabled.
DO:CAP_OK(OFF)
Note: if need change this setting, turn off CAP
function to write in.
x.Bit1 =
1
After capturing the first data, automatically set the
current position as the first position reset
data(PC45).
x
.Bit2 =
1
After capturing the first data, if PC50 d.Bit0 = 0,
activate CMP function(PC50 x.Bit0 = 1) and reset
PC49 to previously value, but this setting is invalid
if CMP function is already activated.
If PC50 d.Bit0 = 1, the high speed CMP function
is enabled(PC50 x.Bit0 = 1).
x
.Bit3 =
1
Execute PR#50 after capturing is completed.
y: source option of Capture
y=0: capture is not working
y=1: auxiliary encoder
y=2: motor feedback position
y=3: CN1( pulse command)
z: capture DI: DI7 trigger edge
z=0: rising edge trigger
z=1: falling edge trigger
u(HEX): trigger minimum interval (unit: ms)
All 2010h
0
~
F13Fh
N/A
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...