14.2 Regenerative resistor
Drive model
name
Built-in regenerative resistor specification
Resistance
value
(Ω)
Capacity
(W)
PA10
Regenerative
resistance value
PA11
Regenerative resistance
capacity.
SDP-010A2C
100
20
100
20
SDP-020A2C
100
20
100
20
SDP-040A2C
100
20
100
20
SDP-075A2C
40
40
40
40
SDP-100A2C
40
40
40
40
SDP-150A2C
13
100
13
100
SDP-200A2C
13
100
13
100
SDP-300A2C
13
100
13
100
★
When using external regenerative resistor, the terminal P,D should be open-circuited.
Drive model
name
Specification of external resistor(proposed)
Resistor Part
Number
Min
allowance
resistance
value
(Ω)
Recommended
capacity
(W)
PA10
Regenerative
resistance
value
PA11
Regenerative
resistance
capacity
SDP-010A2C
100
300
100
300
ABR-300W100
SDP-020A2C
100
300
100
300
ABR-300W100
SDP-040A2C
100
300
100
300
ABR300W100
SDP-075A2C
40
500
40
500
ABR-500W40
SDP-100A2C
40
500
40
500
ABR-500W40
SDP-150A2C
13
1000
13
1000
ABR-1000W13
SDP-200A2C
13
1000
13
1000
ABR-1000W13
SDP-300A2C
13
1000
13
1000
ABR-1000W13
SDP-200A4C
30
1000
30
1000
ABR-1000W30
SDP-300A4C
30
1000
30
1000
ABR-1000W30
SDP-500A4C
20
2000
20
2000
ABR-2000W20
SDP-700A4C
15
2000
15
2000
ABR-2000W15
★
When using external regenerative resistor on 400V drive, connect to P,C terminal.
Summary of Contents for SDP Series
Page 33: ...20 400V series DC 24V Power supply Note terminal P N cannot be grounded ...
Page 45: ...32 4 The last step is to fasten the screw of housing ...
Page 385: ...372 ...
Page 405: ...392 ...
Page 499: ...486 SME L040 SME L075 SME L100 SME L150 ...
Page 500: ...487 SME L200 SME L300 SME M100 SME M150 ...
Page 509: ...496 When the load reaches 300 the operation time is 5 51 seconds ...
Page 555: ...542 14 5 Manual version and revision history Manual version V1 00 Release month July 2022 ...