  Original instructions . . . . . . . . . . . . . . . . . . . . . . . Page . . . . . . . 2

Please order bracket sets separately 

Standard version without tube

Version with tube

E 222052

C

US

DXD 150-BSY+ (-HS)
DXD 300-BSY+ (-HS)

Summary of Contents for 150-BSY+

Page 1: ...99 831 05 1 1 10 15 en Original instructions Page 2 Please order bracket sets separately Standard version without tube Version with tube E 222052 C US DXD 150 BSY HS DXD 300 BSY HS ...

Page 2: ...rved Intended use Rack and pinion drive for electric opening and closing of heavy windows and flaps in the facade and roof area Operating voltage 24 V DC Usheable for smoke ventilation D H Euro SHEV according to DIN EN 12101 2 as well as daily natural ventilation Only for inside mounting Performance features Microprocessor controlled synchro electronics BSY for a precise synchronous run of up to 8...

Page 3: ...Nominal force 1500 N 1500 N 3000 N 3000 N Nominal locking force 1100 N 2200 N Lifetime 10 000 double strokes Duty cycle 30 with cycle time 10 minutes Housing anodized aluminium polycarbonate Ingress protection IP64 Temperature range 5 75 C 23 167 F Fire stability 30 min 300 C 572 F Nominal stroke length see type plate Additional functions closing edge protection activated 3 stroke repeatings progr...

Page 4: ... n 5 m m 0 2 X OPEN magnet N S Stroke shortening Shift slotted pins and magnets into desired position using a suitable tool e g a screw driver for stroke shortening Observe minimum distances 60 mm and 5 mm 2 4 and 0 2 After shifting of the CLOSED magnet let the drive run closed In this process it will be automatically set on a new zero point View X slotted pin slotted pin 2 magnets Shifting of dri...

Page 5: ...rately and disposed of in an environmentally correct manner Disposal Guarantee You will get 2 years guarantee for all D H products from date of verified handing over of the system up to maximal 3 years after date of delivery when mounting and starting has been carried out by an authorized D H distributor D H guarantee is expired with connection of D H components with external systems or with mixin...

Page 6: ... Data A GN Data B GR SZ GN SZ PK SA YE SA WH n c BN n c OR n c Standard WH Mot a BN Mot b OR HS YE Data A GN Data B second connecting cable Connection 1 2 3 4 5 L 6 N 7 Z A E X a b LT Group Monitoring Mot a Mot b MOT BK BK OR 2x47kW En dm od ul Te rm ina l mo du le Mo du le ter mi na l EM 47 K WH BN OR YE GN Mot a Mot b HS Data a Data b DXD BSY Master 1 Junction box WH white BN brown OG orange YE ...

Page 7: ...e instructions for use of control panel Connection 1 2 3 4 5 L 6 N 7 Z A E X a b LT Group Monitoring Mot a Mot b MOT BK BK OR 2x47kW En dm od ul Te rm ina l mo du le Mo du le ter mi na l EM 47 K WH WH BN BN OR OR YE YE GN GN Mot a Mot a Mot b Mot b HS HS Data a Data a Data b Data b Slave 1 Master 2 Junction box to control panel DXD BSY DXD BSY Normal mode SHEV fast running High Speed High Speed Hi...

Page 8: ... 32 Germany 22949Ammersbek 49 239 Tel 40 605 65 49 Fax 40 605 65 254 E Mail info dh partner com www dh partner com 2012 D H Mechatronic AG Ammersbek Rights to technical modifications reserved 100 Recycled paper All sizes in millimetre inches without tube 187 mm 7 4 Stroke 206 mm 8 11 Stroke 226 mm 8 9 182 7 2 with tube Stroke 213 5 mm 8 4 Stroke 240 5 mm 9 47 ...