Chapter 22 Supply Voltage Sensor - (BATSV2)
S12ZVHY/S12ZVHL Family Reference Manual Rev. 1.05
748
Freescale Semiconductor
22.3.2.3
BATS Interrupt Enable Register (BATIE)
22.3.2.4
BATS Interrupt Flag Register (BATIF)
Module Base + 0x0002
Access: User read/write
(1)
1. Read: Anytime
Write: Anytime
7
6
5
4
3
2
1
0
R
0
0
0
0
0
0
BVHIE
BVLIE
W
Reset
0
0
0
0
0
0
0
0
= Unimplemented
Figure 22-6. BATS Interrupt Enable Register (BATIE)
Table 22-4. BATIE Register Field Descriptions
Field
Description
1
BVHIE
BATS Interrupt Enable High
— Enables High Voltage Interrupt
.
0 No interrupt will be requested whenever BVHIF flag is set .
1 Interrupt will be requested whenever BVHIF flag is set
0
BVLIE
BATS Interrupt Enable Low
— Enables Low Voltage Interrupt .
0 No interrupt will be requested whenever BVLIF flag is set .
1 Interrupt will be requested whenever BVLIF flag is set .
Module Base + 0x0003
Access: User read/write
(1)
1. Read: Anytime
Write: Anytime, write 1 to clear
7
6
5
4
3
2
1
0
R
0
0
0
0
0
0
BVHIF
BVLIF
W
Reset
0
0
0
0
0
0
0
0
= Unimplemented