Appendix A MCU Electrical Specifications
S12ZVHY/S12ZVHL Family Reference Manual Rev. 1.05
Freescale Semiconductor
787
A.1.10
ADC Conversion Result Reference
The reference voltage V
BG
is measured under the conditions shown in
. The value stored in the
IFR is the average of 8 consecutive conversions.
2
P
T
A
= 125
C
I
SUPS
280
500
A
3
C
T
A
= 25
C
I
SUPS
23
A
Stop Current with 32K OSC and RTC
4
C
T
A
=25
C
I
SUPS
60
A
Stop Current with LINPHY0 in standby
5
C
T
A
=25
C
I
SUPS
35
A
Table A-15. Pseudo Stop Current Characteristics
Conditions are: V
SUP
=12V, API, COP & RTI enabled
Num
C
Rating
Symbol
Min
Typ
Max
Unit
Pseudo Stop Current with API, COP and RTI enabled
1
C
T
A
= 25
C
I
SUPS
233
A
Pseudo Stop Current with RTC enabled(clock source from external main OSC)
2
C
T
A
= 25
C
I
SUPS
223
A
Table A-16. Measurement Conditions
Description
Symbol
Value
Unit
Regulator supply voltage
VSUP
5
V
I/O supply voltage
V
DDX, A,M
5
V
ADC clock
f
ADCCLK
2
MHz
ADC sample time
t
SMP
4
ADC clock cycles
Bus frequency
f
bus
32
MHz
Ambient temperature
T
A
150
C
Code execution
from RAM
NVM activity
none
Table A-14. Stop Current Characteristics
Conditions are: V
SUP
=12V