Remote control commands
R&S
®
RTO6
2476
User Manual 1801.6687.02 ─ 05
CHANnel<m>:IQ:SBIF
<IQSidebandIF>
Defines the sideband and the frequency position of complex modulated input signal in
IF range.
Prerequisites:
COMPlex
and
on page 2473 is set to
RFIF
For details, see
Suffix:
<m>
.
1..4
Selects the input channel.
Parameters:
<IQSidebandIF>
NUPPer | NLOWer | IUPPer | ILOWer
NUPPer: Upper sideband in normal position
NLOWer: Lower sideband in normal position
IUPPer: Upper sideband in inverse position
ILOWer: Lower sideband in inverse position
*RST:
NUPPer
Usage:
Asynchronous command
CHANnel<m>:IQ:WARNing[:STATe]?
Returns ON if the sampling setup results in an unfavorable combination.
To get the message, use
CHANnel<m>:IQ:WARNing:MESSage?
Suffix:
<m>
.
1..4
Return values:
<WarningState>
ON | OFF
*RST:
OFF
Usage:
Query only
CHANnel<m>:IQ:WARNing:MESSage?
CHANnel<m>:IQ:WARNing[:STATe]?
is true.
Suffix:
<m>
.
1..4
Return values:
<WarningMessage> The string is:
"Undersampling" if the carrier frequency is too fast.
"CF + BW/2 > DevBW" if bandwidth serttings do not fit. CF is the
carrier frequency, BW is the filter bandwidth, and DevBW is the
maximum instrument bandwidth.
Usage:
Query only
I/Q software interface (option R&S