Protocol analysis
R&S
®
RTO6
630
User Manual 1801.6687.02 ─ 05
Column
Description
Type
Frame type: Frame of the static segment, frame of the dynamic segment, wakeup
frame, symbol in the frame
Flags
State of indicator bits
Payload length
Number of data words in the payload segment.
Frame ID
Value of the frame ID (slot number)
Label
Symbolic label name defined in the label list
HCRC
Value of the header CRC
FCRC
Value of the frame CRC
Cycle count
Number of the current FlexRay cycle
Values
Value of the data bytes. The data format is selected below the table. Wakeup and
symbol frames do not transmit data, therefore "- - -" is displayed.
Remote commands
Remote commands are described in
Chapter 24.17.10.3, "Decode results"
13.9.4
Search on decoded FlexRay data
Using the search functionality, you can find various events in the decoded data. You
can find the same events that you can trigger on, and even many more, since several
event types can also be combined.
Before you can start the search, you have to configure the bus correctly and acquire
decoded data.
To search on decoded data, set the search source to "SerBus" for the configured proto-
col.
For general information on how to handle the search functionality, see
13.9.4.1
FlexRay search setup
Access: [Bus] > "Shortcuts" tab > "Setup search"
FlexRay (option R&S
RTO6-K520)