![R&S RTO6 Скачать руководство пользователя страница 986](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_3064646986.webp)
Mixed signal option (MSO, R&S
RTO6-B1)
R&S
®
RTO6
986
User Manual 1801.6687.02 ─ 05
Enable bus
Enables the selected parallel bus. The corresponding signal icon appears on the signal
bar.
If another
active
bus already uses the same digital channel, the instrument disables the
other bus and shows a message.
Remote command:
Show channels
If enabled, the selected digital channels are shown in the diagram. Each channel is dis-
played as a logic signal.
Remote command:
Technology, Threshold
Sets the logical threshold. For each sample, the instrument compares the input voltage
with the threshold value. If the input voltage is above the threshold, the signal state "1"
is stored. Otherwise, the signal state "0" is stored if the input voltage is below the
threshold.
To avoid the change of signal states due to noise, a hysteresis is considered.
Digital channels and parallel buses