Remote control commands
R&S
®
RTO6
2489
User Manual 1801.6687.02 ─ 05
ADVJitter<m>:SIGNal:SAMTime
<SamplingTime>
Sets a sampling time for the explicit clock signal, an offset for the clock edge in relation
to the bit start. The clock edge sets the beginning of the unit interval. The sampling
time is a number between 0 and 1. Value 0 sets the clock edge to the beginning of the
bit period; value 0.5 sets the clock edge to the middle of the bit period.
Suffix:
<m>
.
1..2
Parameters:
<SamplingTime>
Range:
0 to 1
Increment: 0.01
*RST:
0.5
Default unit: UI
ADVJitter<m>:SIGNal:GATE:COUPling
<ModeType>
Sets if the gate is coupled to the zoom or cursor.
Suffix:
<m>
.
1..2
Parameters:
<ModeType>
NONE | CURSor | ZOOM
*RST:
NONE
ADVJitter<m>:SIGNal:GATE:CURSor
<CursorType>
Sets the cursor the gate is coupled to, if
ADVJitter<m>:SIGNal:GATE:COUPling
is set to
CURSor
.
Suffix:
<m>
.
1..2
Parameters:
<CursorType>
CURSOR1 | CURSor1 | CURSOR2 | CURSor2 | CURSOR3 |
CURSor3 | CURSOR4 | CURSor4
*RST:
CURSOR1
ADVJitter<m>:SIGNal:GATE:RANGe:ABSolute:STARt
<StartValue>
Sets the start time of the gate area in percent, if
is set to
ABS
.
Suffix:
<m>
.
1..2
Parameters:
<StartValue>
Range:
-100E+24 to 100E+24
Increment: 0.01
*RST:
0
Jitter analysis and clock data recovery