Protocol analysis
R&S
®
RTO6
762
User Manual 1801.6687.02 ─ 05
Sequence Stop ← Type
Triggers on the end of a command sequence, on the bus park cycle.
Optionally, you can specify a slave address pattern or a slave address range to trigger
only on command sequences that are sent to these slaves.
Register 0 Write ← Type
Triggers on "Register 0 Write" command sequences. This sequence sends 7 data bits
in the command payload.
You can refine the trigger condition:
●
Set a slave address condition to trigger only on command sequences that are sent
to the specified slaves.
See:
●
Set a data pattern condition to trigger on data patterns expected in the message.
See:
Register Write ← Type
Triggers on "Register Write" command sequences. This sequence sends the register
address in the command payload, and sends one data frame.
You can refine the trigger condition:
●
Set a slave address condition to trigger only on command sequences that are sent
to the specified slaves.
See:
●
Set a register address condition to trigger only on command sequences that write
data to the specified register.
See:
●
Set a data pattern condition to trigger on data patterns expected in the message.
See:
Register Read ← Type
Triggers on "Register Read" command sequences. This sequence sends the register
address in the command payload, and reads back one data frame.
You can refine the trigger condition using the same settings as for the "Register Write"
command sequence, see
Extended Register Write ← Type
Triggers on "Extended Register Write" command sequences. This sequence sends the
byte count of data frames in the command payload, followed by one address frame
with the address of the first extended register, and up to 16 data frames.
You can refine the trigger condition:
●
Set a slave address condition to trigger only on command sequences that are sent
to the specified slaves.
See:
●
Set a byte count condition to trigger only on command sequences that send the
specified number of data frames.
See:
●
Set a register address condition to trigger only on command sequences that write
data to the specified register.
RFFE (option R&S