![R&S RTO6 Скачать руководство пользователя страница 1278](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_30646461278.webp)
Remote control commands
R&S
®
RTO6
1278
User Manual 1801.6687.02 ─ 05
//Configure current probe on CH2 manually
//Always required because R&S current probes are not recognized automatically
PROBe2:SETup:ATTenuation:MODE Manual
PROBe2:SETup:ATTenuation:DEFProbe ZC20
*OPC?
//select 20MHz current probe ZC10 also possible
//Start deskew
//Overwrites the skew offset of CH2 (current probe), because :POWer:DESKew:RESet? == 1
//writes a user-defined preset file (UserDefinedPreset_AutoDeskew.dfl) and
//activates the user defined preset, because :POWer:DESKew:UDPReset? == 1
:PoWer:DESKew:EXECute;
//Check result
CHANnel2:SKEW:MAN?
CHANnel2:SKEW:TIMe?
POWer:DESKew:TIMe?
*OPC?
Effect of *RST and loading user-defined preset
Note that
*RST
resets the deskew values.
You can reload the deskew values as follows:
*RST;*OPC?
STOP;*OPC?
:POWer:ENABle
//Select voltage and current sources
:POWer:SOURce:VOLTage1 CHANnel1
:POWer:SOURce:CURRent1 CHANnel2
*OPC?
//Reload deskew values
:POWer:DESKew:CURRent
*OPC?
//Load default saveset after FW restart
MMEM:RCL 'C:\Users\Public\Documents\Rohde-Schwarz\RTx\SaveSets
\UserDefinedPreset_AutoDeskew.dfl'
24.3.8.2
Transient response measurement
Configures and executes a transient response measurement.
Command description in
Chapter 24.23.15, "Transient response"
Make sure to configure and deskew the probes before the measurement, see
//Activate power
*RST; *OPC?
Programming examples