![R&S RTO6 Скачать руководство пользователя страница 519](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_3064646519.webp)
Protocol analysis
R&S
®
RTO6
519
User Manual 1801.6687.02 ─ 05
Type
Sets the event to be searched for.
"Frame start
(SS)"
Searches for the start of the frame when slave select signal SS
changes to the active state. This type is available if the slave select
line is configured in the bus setup, and the frame condition is "SS".
"Frame start
(Timeout)"
Searches for the start of the frame when the clock idle time exceeds
the timeout. This trigger type is available if frame condition is set to
"CLK timeout".
"MOSI"
Searches for a specified data pattern expected on the MOSI line.
"MISO"
Searches for a specified data pattern expected on the MISO line.
"MOSI / MISO" Searches for specified data patterns expected on the MOSI and
MISO lines.
Remote command:
MOSI and MISO data search
The MOSI and MISO setup consists of the condition, position, MOSI pattern, MISO
pattern, search mode (word-aligned, bit-aligned) and one or two index patterns.
The MOSI and MISO setup settings are the same as in the SPI trigger setup. For
details, see
"MOSI and MISO data conditions"
SPI bus (option R&S
RTO6-K510)