Remote control commands
R&S
®
RTO6
1891
User Manual 1801.6687.02 ─ 05
INRange | OORange
In range, Out of range: Set the minimum and maximum value of
the range with
and
*RST:
OFF
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:PMAX
<SearchName>,<PayloadLengthTo>
SEARch:TRIGger:FLXRay:PMAX?
<SearchName>
Sets the the end value of a payload length range if the condition
is set to
INRange
or
OORange
.
Parameters:
<PayloadLengthTo> Range:
0 to 127
Increment: 1
*RST:
0
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:PMIN
<SearchName>,<PayloadLength>
SEARch:TRIGger:FLXRay:PMIN?
<SearchName>
Specifies a payload length - the number of words in the payload segment - or sets the
the start value of an payload length range. Information is transmitted in 2-byte words,
so the number of data bytes in the payload segment is twice the payload length.
Parameters:
<PayloadLength>
Range:
0 to 127
Increment: 1
*RST:
0
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:FLXRay:STFRame
<SearchName>,<StartupFrame>
SEARch:TRIGger:FLXRay:STFRame?
<SearchName>
Searches for startup frames used for startup of the network. Only specific start nodes
can send this frame type.
Parameters:
<StartupFrame>
ONE | ZERO | DC
Bit value: 1, 0, or X (don't care)
*RST:
DC
Parameters for setting and query:
<SearchName>
Protocols