Remote control commands
R&S
®
RTO6
1625
User Manual 1801.6687.02 ─ 05
NOT
Input value is inverted
Parameters for setting and query:
<Searchname>
String with the name of the search
Usage:
Asynchronous command
SEARch:TRIGger:PATTern:AB:LOGic
<Searchname>, <Operator>
SEARch:TRIGger:PATTern:AB:LOGic?
<Searchname>
SEARch:TRIGger:PATTern:CD:LOGic
<Searchname>, <Operator>
SEARch:TRIGger:PATTern:CD:LOGic?
<Searchname>
SEARch:TRIGger:PATTern:ABCD:LOGic
<Searchname>, <Operator>
SEARch:TRIGger:PATTern:ABCD:LOGic?
<Searchname>
Defines the logical combination of the indicated channels after evaluating the previous
logical operations:
●
AB: CH1 and CH2
●
CD: CH3 and CH4
●
ABCD: result of AB and CD
Parameters:
<Operator>
AND | NAND | OR | NOR
AND: logical AND, conjunctive combination
NAND:logical NOT AND
OR:logical OR, disjunctive combination
NOR: logical NOT OR
Parameters for setting and query:
<Searchname>
String with the name of the search
Usage:
Asynchronous command
SEARch:TRIGger:PATTern:MODE
<SearchName>,<Mode>
SEARch:TRIGger:PATTern:MODE?
<SearchName>
Adds additional time limitation to the pattern definition.
Parameters:
<Mode>
OFF | TIMeout | WIDTh
OFF
No time limitation. The event is found if the pattern condition is
fulfilled.
TIMeout
Defines how long the result of the pattern condition stays high or
low. The duration of the timeout is defined using
TRIGger:PATTern:TIMeout[:TIME]
SEARch:TRIGger:PATTern:TIMeout:MODE
.
Search