![R&S RTO6 Скачать руководство пользователя страница 1907](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_30646461907.webp)
Remote control commands
R&S
®
RTO6
1907
User Manual 1801.6687.02 ─ 05
Parameters:
<SMIDPatternTo>
Chapter 24.4.6, "Bit pattern parame-
on page 1286. The string parameter accepts the bit value X
(don't care).
TRIGger<m>:SENT:SDCN
<SMDataOperator>
Sets the operator to set a specific data pattern or a data pattern range.
Parameters:
<SMDataOperator>
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater than,
Greater or equal than. These conditions require one data pattern
to be set with
.
INRange | OORange
In range / Out of range. To define the range set the minimum
and maximum values with
*RST:
EQUal
TRIGger<m>:SENT:SDMN
<SMDataPattern>
Specifies a data pattern, or sets the start value of a data pattern range.
Parameters:
<SMDataPattern>
Chapter 24.4.6, "Bit pattern parame-
on page 1286. The string parameter accepts the bit value X
(don't care).
TRIGger<m>:SENT:SDMX
<SMDataPatternTo>
Sets the end value of an identifier range for
.
Parameters:
<SMDataPatternTo> Numeric or string pattern,
Chapter 24.4.6, "Bit pattern parame-
on page 1286. The string parameter accepts the bit value X
(don't care).
TRIGger<m>:SENT:FORMerror
<FormError>
Triggers on format errors in serial messages.
A form error occurs when at least one of the transmission sequences that form a serial
message has an error.
Protocols