Remote control commands
R&S
®
RTO6
2324
User Manual 1801.6687.02 ─ 05
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less than or equal, Greater than,
Greater than or equal. These conditions require one endpoint
value to be set using
TRIGger<m>:MPHY:SSIC:FRAMe<n>:
INRange | OORange
In range, out of range. These conditions require a range of end-
point values to be set using
*RST:
EQUal
TRIGger<m>:MPHY:SSIC:IMAX
<Frame>, <Field>, <Data>
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:IMAX
<IndexMax>
Sets the end value of an index range if
TRIGger<m>:MPHY:SSIC:FRAMe<n>:
is set to
INRange
or
RANGe
.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
<n>
*
Specifies the field number within the frame.
<o>
*
Parameters:
<IndexMax>
Specifies the end value for the index range within the field.
The index range, increment and *RST values depend on the
field type.
TRIGger<m>:MPHY:SSIC:IMIN
<Frame>, <Field>, <Data>
TRIGger<m>:MPHY:SSIC:FRAMe<n>:FLD<o>:IMIN
<IndexMin>
Specifies the index, or sets the start value of an index range.
Suffix:
<m>
.
1..3
<n>
*
Specifies the field number within the frame.
<o>
*
Parameters:
<IndexMin>
Specifies the index value or index start value within the field.
The index range, increment and *RST values depend on the
field type.
Range:
1 to 65534
Increment: 1
*RST:
1
Protocols