Remote control commands
R&S
®
RTO6
1746
User Manual 1801.6687.02 ─ 05
INRange | OORange
In range, Out of range: Set the minimum and maximum value of
the range with
TRIGger<m>:I2S:TCONdition<n>:DMIN
and
TRIGger<m>:I2S:TCONdition<n>:DMAX
*RST:
OFF
TRIGger<m>:I2S:TCONdition<n>:DMIN
<DataMinPattern>
Specifies a data pattern, or sets the the start value of a data pattern range.
Suffix:
<n>
.
1..4
1 if trigger type is DATA or WINDow
Specifies the condition number if trigger type is CONDition:
–
1 | 2 for I²S standard, left- und right-justified data formats
–
1 | 2 | 3 | 4 for TDM signals
Parameters:
<DataMinPattern>
Numeric pattern in 2's complement format. See also:
ter 24.4.6, "Bit pattern parameter"
X bits are not allowed. If the bit string is shorter than the word
length, the rightmost bit of the input bit string is aligned to the
rightmost (LSB) bit of the word.
TRIGger<m>:I2S:TCONdition<n>:DMAX
<DataMaxPattern>
Sets the the end value of an data range if the operator
is set to
INRange
or
OORange
.
Suffix:
<n>
.
1..4
1 if trigger type is DATA or WINDow
Specifies the condition number if trigger type is CONDition:
–
1 | 2 for I²S standard, left- und right-justified data formats
–
1 | 2 | 3 | 4 for TDM signals
Parameters:
<DataMaxPattern>
Numeric pattern in 2's complement format. See also:
ter 24.4.6, "Bit pattern parameter"
DMAX must be greater or equal than DMIN.
X bits are not allowed. If the bit string is shorter than the word
length, the rightmost bit of the input bit string is aligned to the
rightmost (LSB) bit of the word.
TRIGger<m>:I2S:SOWords
<SequenceOfWords>
Sets the number of words that is used as time limit for the "Window" trigger type. The
instrument triggers if the data condition is fulfilled on the same channel for the given
number of subsequent frames.
Protocols