Protocol analysis
R&S
®
RTO6
904
User Manual 1801.6687.02 ─ 05
Data
Sets the data to be triggered on. The trigger data setup consists of a comparison con-
dition and one or two data patterns.
"Condition"
Sets the comparison condition to a specific value or a range.
"Data Min/Data"
Specifies the value or sets the start value of a range.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor"
"Data Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command:
Index
The trigger index setup consists of a comparison condition and one or two address pat-
terns.
"Condition"
Sets the comparison condition to a specific value or a range.
"Index Min/Index"
Specifies the value or sets the start value of a range.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor"
"Index Max"
Sets the maximum value of a range for "Condition" = "In range"/"Out
of range".
Remote command:
TRIGger<m>:MPHY:DATA:ICONdition
FSN
Sets the specified Frame Sequence Number (FSN) to be triggered on. The FSN setup
consists of the condition and one or two FSN patterns.
"Condition"
Defines the operator to set a specific FSN, e.g. "Equal" or "Not Equal"
or a range.
"Data Min/Data"
Defines the bit pattern of the FSN pattern.
In binary format, use the following characters: 1; 0; or X (do not care).
To enter the pattern in other formats use the bit pattern editor, see
Chapter 13.1.7, "Bit pattern editor"
"Data Max"
The second FSN pattern is required to specify a range with conditions
"In range" and "Out of range".
M-PHY and USB SSIC (option R&S