Remote control commands
R&S
®
RTO6
1416
User Manual 1801.6687.02 ─ 05
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Parameters:
<ScanMode>
INTerlaced | PROGressive | SEGMented
SEGMented: Progressive segmented frame uses progressive
scanning to capture the frame, and interlaced scanning for trans-
mission and display.
*RST:
INTerlaced
Usage:
Asynchronous command
TRIGger<m>:TV:CUSTom:LDURation
<LinePeriod>
Sets the duration of a line, the time between two successive sync pulses. Only relevant
if
CUSTom
.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Parameters:
<LinePeriod>
Range:
1E-6 to 500E-6
Increment: 100E-9
*RST:
64E-6
Default unit: s
Usage:
Asynchronous command
TRIGger<m>:TV:CUSTom:STYPe
<SyncPulseType>
Sets the type of the sync pulse. Only relevant if
CUSTom
.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Parameters:
<SyncPulseType>
BILevel | TRILevel
BILevel
Bi-level sync pulse, usually used in SDTV signals
TRILevel
Tri-level sync pulse, used in HDTV signals
*RST:
BILevel
Usage:
Asynchronous command
Trigger