Remote control commands
R&S
®
RTO6
2050
User Manual 1801.6687.02 ─ 05
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:MDIO:PHYS
<SearchName>,<PhyAddr>
SEARch:TRIGger:MDIO:PHYS?
<SearchName>
Allows to set the physical address (in Clause
22) or port address (in Clause
45) of the
frame pattern (5
bits); available only in search criteria type "Data".
Parameters:
<PhyAddr>
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:MDIO:REGI
<SearchName>,<RegAddr>
SEARch:TRIGger:MDIO:REGI?
<SearchName>
Allows to set the register address (in Clause
22) or device address (in Clause
45) of
the frame pattern (5
bits); available only in search criteria type "Data".
Parameters:
<RegAddr>
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:MDIO:ST
<SearchName>,<StartCode>
SEARch:TRIGger:MDIO:ST?
<SearchName>
Allows to select the start of frame code of the frame pattern; available only in search
criteria type "Data".
Parameters:
<StartCode>
ST00 | ST01 | ST0X
ST00
Clause 45
ST01
Clause 22
ST0X
Any permissible start pattern
*RST:
ST0X
Parameters for setting and query:
<SearchName>
Protocols