![R&S RTO6 Скачать руководство пользователя страница 1876](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_30646461876.webp)
Remote control commands
R&S
®
RTO6
1876
User Manual 1801.6687.02 ─ 05
Parameters:
<DataPosition>
Range:
0 to 255
Increment: 1
*RST:
0
TRIGger<m>:FLXRay:DPTO
<DataPositionTo>
Defines the last byte of interest, if the position operator
defines a range.
Parameters:
<DataPositionTo>
Range:
0 to 255
Increment: 1
*RST:
0
TRIGger<m>:FLXRay:DCONdition
<DataOperator>
Sets the operator to set a specific data pattern or a data pattern range.
Parameters:
<DataOperator>
OFF | ANY | EQUal | NEQual | LTHan | LETHan | GTHan |
GETHan | INRange | OORange
OFF = ANY
The data position is not relevant for the trigger condition.
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one data posi-
tion to be set with
INRange | OORange
In range, Out of range: Set the minimum and maximum value of
the range with
and
*RST:
EQUal
TRIGger<m>:FLXRay:DMIN
<DataPattern>
Specifies a data pattern, or sets the the start value of a data pattern range.
Parameters:
<DataPattern>
Numeric or string pattern, see
on page 1286. The string parameter accepts the bit
value X (don't care).
TRIGger<m>:FLXRay:DMAX
<DataPatternTo>
Sets the the end value of an data range if the operator
is set to INRange or OORange.
Protocols