![R&S RTO6 Скачать руководство пользователя страница 603](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_3064646603.webp)
Protocol analysis
R&S
®
RTO6
603
User Manual 1801.6687.02 ─ 05
Message
Sets the message to be triggered or searched for.
The setting is used by symbolic trigger and symbolic search. Thus, you always trigger
on and search for the same message if symbolic trigger and symbolic search is used at
the same time.
Remote command:
SEARch:TRIGger:CAN:SYMBolic:MSGValue
Search signals
Enables the search for a specific signal value that is part of the selected message.
Remote command:
SEARch:TRIGger:CAN:SYMBolic:SSIGnals
Signal
Sets the signal name to be triggered or searched for.
The setting is used by symbolic trigger and symbolic search. Thus, you always trigger
on and search for the same signal if symbolic trigger and symbolic search is used at
the same time.
Remote command:
SEARch:TRIGger:CAN:SYMBolic:SIGValue
Condition
Sets the operator to set a specific data pattern or symbolic value ("Equal" or "Not
equal") or a data range.
This condition is also used to search for data, see
"Data setup: DLC, NDB, Condition,
Remote command:
Value, Value (min)
Defines the data pattern or selects a symbolic data value.
Remote command:
SEARch:TRIGger:CAN:SYMBolic:DMIN
SEARch:TRIGger:CAN:SYMBolic:SGEValue
Value (max)
The second data pattern is required to specify a range with conditions "In range" and
"Out of range".
Remote command:
SEARch:TRIGger:CAN:SYMBolic:DMAX
13.7.6.4
Symbolic search results
If a DBC file is applied, you can search for symbolic messages and signals as descri-
bed in
Chapter 13.7.6.3, "Symbolic search"
on page 602. As ususal, the search results
CAN and CAN FD (option R&S
RTO6-K520)