SEARch:RESult:CMSB<m>:FRAMe<n>:CELL<o>:STATe?
<SearchName>
Returns the state of the cell within the search result.
Suffix:
<m>
.
*
<n>
*
<o>
*
Query parameters:
<SearchName>
Return values:
<State>
OK | LENGth | UNKNown | INComplete | CRC | PARity
OK
No error detected
LENGth
The length error indicates that the cell ended prematurely. The
amount of bits that the software expected (based upon the
user's frame description) was not found before the cell was ter-
minated. This might occur because a new frame synchronized,
or a gap appeared between the bits.
UNKNown
Unknown error
INComplete
The cell ended prematurely because it extends past the end of
the record.
CRC
Checksum error in cyclic redundancy check (error in data)
PARity
Parity bit error, indicating a transmission error (only available if a
parity is configured)
*RST:
OK
Usage:
Query only
SEARch:RESult:CMSB<m>:FRAMe<n>:CELL<o>:STOP?
<SearchName>
Returns the stop time of the cell within the search result.
Suffix:
<m>
.
*
<n>
*
<o>
*
Query parameters:
<SearchName>
Protocols