![R&S RTO6 Скачать руководство пользователя страница 1196](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_30646461196.webp)
Power analysis (option R&S
RTO6-K31)
R&S
®
RTO6
1196
User Manual 1801.6687.02 ─ 05
The following remote commands are used for handling the measurement results:
●
●
POWer:SPECtrum:RESult<m>:FREQuency?
●
POWer:SPECtrum:RESult<m>:LEVel?
●
19.6.3.2
Configuring output spectrum
For details of the configuration settings, see
Chapter 19.6.3.3, "Output spectrum set-
1. Select "Analysis">"Power".
2. Under "Output", select "Spectrum".
3. Select the "Channels" tab.
4. Connect the probe to the DUT and to the oscilloscope as shown in the graphic:
5. Select the correct channel for the "Voltage Source".
6. Select the "Settings" tab.
7. Set the "SMPS switching frequency" according to your signal.
8. Select an "Optimize Scaling"option.
Output