A.13 List of Information
555
7UM62 Manual
C53000-G1176-C149-3
01809 O/C I>> TRIP (I>> TRIP)
O/C I>> (with direc-
tion)
OUT
*
ON
M
LED
BO
60
211
2
GI
01811 O/C fault detection stage I> phase L1
(I> Fault L1)
O/C I> (with under-
voltage seal-in)
OUT
*
ON
OFF
LED
BO
60
50
2
GI
01812 O/C fault detection stage I> phase L2
(I> Fault L2)
O/C I> (with under-
voltage seal-in)
OUT
*
ON
OFF
LED
BO
60
51
2
GI
01813 O/C fault detection stage I> phase L3
(I> Fault L3)
O/C I> (with under-
voltage seal-in)
OUT
*
ON
OFF
LED
BO
60
52
2
GI
01815 O/C I> TRIP (I> TRIP)
O/C I> (with under-
voltage seal-in)
OUT
*
ON
M
LED
BO
60
71
2
GI
01883 >BLOCK inverse O/C time protection
(>BLOCK O/C Ip)
Inverse O/C Time
Protection
SP
*
*
LED BI
BO
01891 O/C protection Ip is switched OFF (O/
C Ip OFF)
Inverse O/C Time
Protection
OUT
ON
OF
F
*
LED
BO
60
180
1
GI
01892 O/C protection Ip is BLOCKED (O/C Ip
BLOCKED)
Inverse O/C Time
Protection
OUT
ON
OF
F
ON
OFF
LED
BO
60
181
1
GI
01893 O/C protection Ip is ACTIVE (O/C Ip
ACTIVE)
Inverse O/C Time
Protection
OUT
ON
OF
F
*
LED
BO
60
182
1
GI
01896 O/C fault detection Ip phase L1 (O/C
Ip Fault L1)
Inverse O/C Time
Protection
OUT
*
ON
OFF
LED
BO
60
184
2
GI
01897 O/C fault detection Ip phase L2 (O/C
Ip Fault L2)
Inverse O/C Time
Protection
OUT
*
ON
OFF
LED
BO
60
185
2
GI
01898 O/C fault detection Ip phase L3 (O/C
Ip Fault L3)
Inverse O/C Time
Protection
OUT
*
ON
OFF
LED
BO
60
186
2
GI
01899 O/C Ip picked up (O/C Ip pick.up)
Inverse O/C Time
Protection
OUT
*
ON
OFF
LED
BO
60
183
2
GI
01900 O/C Ip TRIP (O/C Ip TRIP)
Inverse O/C Time
Protection
OUT
*
ON
M
LED
BO
60
187
2
GI
01950 >O/C prot. : BLOCK undervoltage
seal-in (>Useal-in BLK)
O/C I> (with under-
voltage seal-in)
SP
ON
OF
F
*
LED BI
BO
60
200
1
GI
01955 O/C prot. stage I>> is switched OFF
(I>> OFF)
O/C I>> (with direc-
tion)
OUT
ON
OF
F
*
LED
BO
60
205
1
GI
01956 O/C prot. stage I>> is BLOCKED (I>>
BLOCKED)
O/C I>> (with direc-
tion)
OUT
ON
OF
F
ON
OFF
LED
BO
60
206
1
GI
01957 O/C prot. stage I>> is ACTIVE (I>>
ACTIVE)
O/C I>> (with direc-
tion)
OUT
ON
OF
F
*
LED
BO
60
207
1
GI
01965 O/C prot. stage I> is switched OFF (I>
OFF)
O/C I> (with under-
voltage seal-in)
OUT
ON
OF
F
*
LED
BO
60
215
1
GI
F.No.
Description
Function
Type
of
Infor-
matio
n
Log-Buffers
Configurable in Matrix
IEC 60870-5-103
E
v
en
t
L
o
g
On
/O
ff
T
rip
(F
au
lt)
L
o
g
On
/Of
f
Gr
o
u
n
d
F
a
u
lt
L
o
g
O
n
/Of
f
M
a
rk
e
d
in
Osc
ill.
Reco
rd
LED
Bi
n
a
ry
In
p
u
t
Fun
ct
io
n
K
e
y
B
ina
ry
O
u
tp
ut
C
h
at
te
r
B
lo
c
k
in
g
Ty
pe
In
fo
rm
a
ti
on
-N
o
D
a
ta
Un
it
(A
SDU)
G
e
ne
ra
l
In
te
rr
oga
ti
o
n