A Appendix
558
7UM62 Manual
C53000-G1176-C149-3
04576 External trip 3: General picked up (Ext
3 picked up)
External Trip
Functions
OUT
*
ON
OFF
LED
BO
51
176
2
GI
04577 External trip 3: General TRIP (Ext 3
Gen.TRP)
External Trip
Functions
OUT
*
ON
LED
BO
51
177
2
GI
04583 >BLOCK external trip 4 (>BLOCK Ext
4)
External Trip
Functions
SP
*
*
LED BI
BO
04586 >Trigger external trip 4 (>Ext trip 4)
External Trip
Functions
SP
ON
OF
F
*
LED BI
BO
51
186
1
GI
04591 External trip 4 is switched OFF (Ext 4
OFF)
External Trip
Functions
OUT
ON
OF
F
*
LED
BO
51
191
1
GI
04592 External trip 4 is BLOCKED (Ext 4
BLOCKED)
External Trip
Functions
OUT
ON
OF
F
ON
OFF
LED
BO
51
192
1
GI
04593 External trip 4 is ACTIVE (Ext 4
ACTIVE)
External Trip
Functions
OUT
ON
OF
F
*
LED
BO
51
193
1
GI
04596 External trip 4: General picked up (Ext
4 picked up)
External Trip
Functions
OUT
*
ON
OFF
LED
BO
51
196
2
GI
04597 External trip 4: General TRIP (Ext 4
Gen.TRP)
External Trip
Functions
OUT
*
ON
LED
BO
51
197
2
GI
04822 >BLOCK Restart inhibit motor (>BLK
Re. Inhib.)
Restart Inhibit for
Motors
SP
*
*
LED BI
BO
04823 >Emergency start rotor (>Emer. Start
Θ
R)
Restart Inhibit for
Motors
SP
ON
OF
F
*
LED BI
BO
168
51
1
GI
04824 Restart inhibit motor is switched OFF
(Re. Inhibit OFF)
Restart Inhibit for
Motors
OUT
ON
OF
F
*
LED
BO
168
52
1
GI
04825 Restart inhibit motor is BLOCKED
(Re. Inhibit BLK)
Restart Inhibit for
Motors
OUT
ON
OF
F
*
LED
BO
168
53
1
GI
04826 Restart inhibit motor is ACTIVE (Re.
Inhibit ACT)
Restart Inhibit for
Motors
OUT
ON
OF
F
*
LED
BO
168
54
1
GI
04827 Restart inhibit motor TRIP (Re. Inhib.
TRIP)
Restart Inhibit for
Motors
OUT
ON
*
LED
BO
168
55
1
GI
04828 >Reset thermal memory rotor (>RM
th.rep.
Θ
R)
Restart Inhibit for
Motors
SP
ON
OF
F
*
LED BI
BO
04829 Reset thermal memory rotor (RM
th.rep.
Θ
R)
Restart Inhibit for
Motors
OUT
ON
OF
F
*
LED
BO
168
50
1
GI
04830 Alarm restart inhibit motor (Re.
Inhib.ALARM)
Restart Inhibit for
Motors
OUT
ON
OF
F
*
LED
BO
F.No.
Description
Function
Type
of
Infor-
matio
n
Log-Buffers
Configurable in Matrix
IEC 60870-5-103
E
v
en
t
L
o
g
On
/O
ff
T
rip
(F
au
lt)
L
o
g
On
/Of
f
Gr
o
u
n
d
F
a
u
lt
L
o
g
O
n
/Of
f
M
a
rk
e
d
in
Osc
ill.
Reco
rd
LED
Bi
n
a
ry
In
p
u
t
Fun
ct
io
n
K
e
y
B
ina
ry
O
u
tp
ut
C
h
at
te
r
B
lo
c
k
in
g
Ty
pe
In
fo
rm
a
ti
on
-N
o
D
a
ta
Un
it
(A
SDU)
G
e
ne
ra
l
In
te
rr
oga
ti
o
n