A Appendix
524
7UM62 Manual
C53000-G1176-C149-3
242
STARPNT SIDE 1
Power System
Data 1
Isolated
Solid Earthed
Isolated
Starpoint of Side 1 is
243
UN-PRI SIDE 2
Power System
Data 1
0.40..800.00 kV
6.30 kV
Rated Primary Voltage side
2
244
STARPNT SIDE 2
Power System
Data 1
Isolated
Solid Earthed
Isolated
Starpoint of side 2 is
246
VECTOR GRP S2
Power System
Data 1
0..11
0
Vector Group Numeral of
Side 2
249
SN TRANSFOR-
MER
Power System
Data 1
0.20..5000.00 MVA
5.30 MVA
Rated Apparent Power of
the Transformer
251
UN GEN/MOTOR
Power System
Data 1
0.40..800.00 kV
6.30 kV
Rated Primary Voltage
Generator/Motor
252
SN GEN/MOTOR
Power System
Data 1
0.20..5000.00 MVA
5.27 MVA
Rated Apparent Power of
the Generator
270
Rated Frequency
Power System
Data 1
50 Hz
60 Hz
50 Hz
Rated Frequency
271
PHASE SEQ.
Power System
Data 1
L1 L2 L3
L1 L3 L2
L1 L2 L3
Phase Sequence
272
SCHEME
Power System
Data 1
Direct connected to
busbar
Unit transformer
connected
Direct connected to
busbar
Scheme Configuration
274A
ATEX100
Power System
Data 1
YES
NO
NO
Storage of th. Replicas w/o
Power Supply
275
FACTOR R SEF
Power System
Data 1
1.0..200.0
37.0
Ratio Prim./Sec. R SEF
276
TEMP. UNIT
Power System
Data 1
Degree Celsius
Degree Fahrenheit
Degree Celsius
Unit of temparature measu-
rement
280
TMin TRIP CMD
Power System
Data 1
0.01..32.00 sec
0.15 sec
Minimum TRIP Command
Duration
281
BkrClosed I MIN
Power System
Data 1
0.04..1.00 A
0.04 A
Closed Breaker Min. Cur-
rent Threshold
295
TRANSDUCER 1
Power System
Data 1
10 V
4-20mA
20mA
10 V
Transducer 1
296
TRANSDUCER 2
Power System
Data 1
10 V
4-20mA
20mA
10 V
Transducer 2
297
TRANSDUCER 3
Power System
Data 1
with filter
without filter
with filter
Transducer 3
302
CHANGE
Change Group
Group A
Group B
Binary Input
Protocol
Group A
Change to Another Setting
Group
401
WAVEFORMTRIG-
GER
Oscillographic
Fault Records
Save with Pickup
Save with TRIP
Start with TRIP
Save with Pickup
Waveform Capture
Addr.
Setting Title
Function
Setting Options
Default Setting
Comments