A Appendix
566
7UM62 Manual
C53000-G1176-C149-3
05401 Failure REF protection (1-3Hz) (Fail
REF 1-3Hz)
Rotor Earth Fault
Protection (1-3Hz)
OUT
ON
OF
F
*
LED
BO
71
131
1
GI
05403 REF prot. (1-3Hz): warning stage
(Re<) (REF 1-3Hz Warn)
Rotor Earth Fault
Protection (1-3Hz)
OUT
ON
OF
F
*
LED
BO
71
133
1
GI
05406 REF prot. (1-3Hz) Re<< picked up
(REF 1-3Hz Fault)
Rotor Earth Fault
Protection (1-3Hz)
OUT
*
ON
OFF
LED
BO
71
136
2
GI
05407 REF prot. (1-3Hz) Re<< TRIP (REF 1-
3Hz Trip)
Rotor Earth Fault
Protection (1-3Hz)
OUT
*
ON
LED
BO
71
137
2
GI
05408 REF prot. (1-3Hz) test passed (Test
REF PASSED)
Rotor Earth Fault
Protection (1-3Hz)
OUT
ON
OF
F
*
LED
BO
71
138
1
GI
05409 REF prot. (1-3Hz) test NOT passed
(Test REF Fail.)
Rotor Earth Fault
Protection (1-3Hz)
OUT
ON
OF
F
*
LED
BO
71
139
1
GI
05410 REF (1-3Hz) 1 Measuring circuit open
(1 Cir. open)
Rotor Earth Fault
Protection (1-3Hz)
OUT
ON
OF
F
*
LED
BO
05411 REF (1-3Hz) 2 Measuring circuits
open (2 Cir. open)
Rotor Earth Fault
Protection (1-3Hz)
OUT
ON
OF
F
*
LED
BO
05473 >BLOCK Stator earth fault protection
(>SEF100 BLOCK)
100% Stator-Earth-
Fault Protection
SP
*
*
LED BI
BO
05476 >Failure 20Hz bias voltage (S/E/F)
(>U20 failure)
100% Stator-Earth-
Fault Protection
SP
ON
OF
F
*
LED BI
BO
71
227
1
GI
05481 S/E/F 100% protection is switched
OFF (SEF100 OFF)
100% Stator-Earth-
Fault Protection
OUT
ON
OF
F
*
LED
BO
71
228
1
GI
05482 Stator earth flt. prot. 100% is BLOK-
KED (SEF100 BLOCKED)
100% Stator-Earth-
Fault Protection
OUT
ON
OF
F
ON
OFF
LED
BO
71
229
1
GI
05483 Stator earth flt. prot. 100% is ACTIVE
(SEF100 ACTIVE)
100% Stator-Earth-
Fault Protection
OUT
ON
OF
F
*
LED
BO
71
230
1
GI
05486 Failure stator earth flt. prot. 100%
(Failure SEF)
100% Stator-Earth-
Fault Protection
OUT
ON
OF
F
*
LED
BO
71
231
1
GI
05487 Stator earth flt. prot.100% Alarm stage
(SEF100 Alarm)
100% Stator-Earth-
Fault Protection
OUT
ON
OF
F
*
LED
BO
71
232
1
GI
05488 Stator earth flt. prot.100%: picked up
(SEF100 PICKUP)
100% Stator-Earth-
Fault Protection
OUT
*
ON
OFF
LED
BO
71
233
2
GI
05489 Stator earth flt. prot.100%: TRIP
(SEF100 TRIP)
100% Stator-Earth-
Fault Protection
OUT
*
ON
LED
BO
71
234
2
GI
05503 >BLOCK Rate-of-frequency-change
prot. (>df/dt block)
Rate-of-frequency-
change protection
SP
*
*
LED BI
BO
F.No.
Description
Function
Type
of
Infor-
matio
n
Log-Buffers
Configurable in Matrix
IEC 60870-5-103
E
v
en
t
L
o
g
On
/O
ff
T
rip
(F
au
lt)
L
o
g
On
/Of
f
Gr
o
u
n
d
F
a
u
lt
L
o
g
O
n
/Of
f
M
a
rk
e
d
in
Osc
ill.
Reco
rd
LED
Bi
n
a
ry
In
p
u
t
Fun
ct
io
n
K
e
y
B
ina
ry
O
u
tp
ut
C
h
at
te
r
B
lo
c
k
in
g
Ty
pe
In
fo
rm
a
ti
on
-N
o
D
a
ta
Un
it
(A
SDU)
G
e
ne
ra
l
In
te
rr
oga
ti
o