QuickStart Guide

MM200 revision: 1.11
Manual P/N: 1601-9030-A4
GE publication code: GEK-113401C
Copyright © 2009 GE Multilin

IISO9001:2000

GE

M ULTILI

N

RE

GISTERED

*1601-9030-A4*

MM200

Motor Management System

Low voltage motor protection and control

Summary of Contents for MM200

Page 1: ...Anderson Avenue Markham Ontario Canada L6E 1B3 Tel 905 294 6222 Fax 905 201 2098 Internet http www GEmultilin com QuickStart Guide MM200 revision 1 11 Manual P N 1601 9030 A4 GE publication code GEK...

Page 2: ...MM200 Setup and FlexLogic are registered trademarks of GE Multilin Inc The contents of this manual are the property of GE Multilin Inc This documentation is furnished on license and may not be reprod...

Page 3: ...ints 13 Configuration setpoints 13 Motor setpoints 13 Common motor setpoints 13 Current transformers 15 Protection elements 16 Thermal protection 16 Overload curve 16 Communications interfaces 19 Spec...

Page 4: ...toc 2 MM200 MOTOR MANAGEMENT SYSTEM QUICKSTART GUIDE TABLE OF CONTENTS...

Page 5: ...tage motor applications The MM200 provides the following key benefits Protection control and communication options to suit low voltage motor applications Small footprint designed specifically for IEC...

Page 6: ...dimensions of the MM200 are shown below Additional dimensions for mounting are shown in the following sections RS485 Modbus RTU Profibus DeviceNet 52 METERING A 51R 49 37 46 50G MOTOR LOAD Temperatur...

Page 7: ...nsions 1 1 1 2 Product identification The product identification label is located on the side panel of the MM200 This label indicates the product model serial number firmware revision and date of manu...

Page 8: ...d below The DIN rail conforms to EN 50022 CAUTION CAUTION To avoid the potential for personal injury due to fire hazards ensure the unit is mounted in a safe location and or within an appropriate encl...

Page 9: ...evicenet are provided as options Table 2 Slot position Figure 7 MM200 terminal connection torque rating CAUTION CAUTION Use gauge size appropriate for the voltage and current draw of the device Slot T...

Page 10: ...nd Rear panel arrangement The MM200 I O terminals are labeled with a two character identifier The first character identifies slot position and the second identifies the terminal Slot A PSU and Inputs...

Page 11: ...e MM200 Figure 9 CBCT ground CT connection HI LO 888351A3 P2 888741A3 CDR A C B Contactor Contactor TO CONTROL PANEL C1 C2 C4 C3 C5 C6 MM200 Motor Management System C8 C9 C10 C7 Two form A contact out...

Page 12: ...ation shielded cable M A1 A2 A4 A3 A5 A6 A8 A9 A10 A7 24 VDC CONTACT INPUTS CONTROL POWER VDC CONTROL POWER 24 VDC FIELD STOP FIELD START RESET M N L A1 A2 A4 A3 A5 A6 A8 A9 A10 L N VAC CONTACT INPUTS...

Page 13: ...13A1 CDR GROUND CONDUCTOR DOES NOT PASS THROUGH CT AS THE CT IS NOT MOUNTED OVER GROUND WITHIN THE CABLE JACKET BOTTOM OF MOTOR STARTER COMPARTMENT CORE BALANCE CT SECONDARY CONNECTION TO MM200 IED 88...

Page 14: ...aisy chained together on a communication channel without exceeding the driver capability For larger systems additional serial channels must be added Commercially available repeaters can also be M A1 A...

Page 15: ...nly as shown in the figure above to avoid ground loops Correct polarity is also essential The MM200 IEDs must be wired with all the positive terminals connected together and all the negative terminals...

Page 16: ...W QUICKSTART GUIDE Figure 16 Basic control panel The following LEDs are provided Two USER LEDs USER 1 and USER 2 the user can select parameters from a list 50 80 100 showing motor load RUNNING STOPPED...

Page 17: ...o digital output configuration Comms setpoints related to communications configuration System setpoints related to MM200 system configuration such as the faceplate LEDs Counters setpoints related to t...

Page 18: ...or low speed motor rating for two speed starters in kWs The following sections provide additional information for each starter type Figure 17 Typical starter timing 1 2 2 3 Current transformers The fo...

Page 19: ...ncreasing the accuracy of the measurement The value of this setting should equal the number of turns on the CT Primary to display the correct current value Internally the current measurement will be d...

Page 20: ...t accounts for heat dissipation Thermal protection reset that controls recovery from thermal trips and lockouts Each of these categories are described in the following sub sections 1 3 1 1 Overload cu...

Page 21: ...me Eq 3 This would respect a safe stall cold time of 10 seconds The standard overload curves are displayed below Figure 18 Standard overload curves The trip times for the standard overload curves are...

Page 22: ...9 98 66 64 83 30 99 96 116 62 133 28 149 94 166 60 183 26 199 92 216 58 233 24 249 90 2 75 13 33 26 65 39 98 53 31 66 64 79 96 93 29 106 62 119 95 133 27 146 60 159 93 173 25 186 58 199 91 3 00 10 93...

Page 23: ...s interfaces RS485 Fieldbus NOTE NOTE Setpoint changes related to RS485 DeviceNet and Profibus require a power cycle to be activated NOTE NOTE External power must be present on the Fieldbus port at po...

Page 24: ...ROUND FAULT CBCT Pickup level 0 5 to 15 0 A in steps of 0 1 A Trip time delay on start 0 to 10 s in steps of 0 1 s Trip time delay on run 0 to 5 s in steps of 0 1 s Alarm time delay on start run 0 to...

Page 25: ...cifications DIGITAL INPUTS LO Fixed pickup 24 V DC Continuous current draw 4 mA Type opto isolated inputs External switch wet contact Maximum input voltage 36 V DC DIGITAL INPUTS HI Nominal voltage 12...

Page 26: ...C 5 A AC resistive 250 V AC 5 A AC inductive PF 0 4 240 VA pilot duty DC resistive 30 V DC 5 A OUTPUT RELAY BREAK CAPACITY FORM C RELAY AC resistive 120 V AC 5 A normally open 5 A normally closed AC r...

Page 27: ...ir and Direct IEC 60255 22 2 15 kV 8 kV Radiated RF Immunity IEC 60255 22 3 10 V m Electrical Fast Transient Burst Immunity IEC 60255 22 4 4 kV Surge Immunity IEC 60255 22 5 2 kV 1 kV Conducted RF Imm...

Page 28: ...erating temperature 1 around base unit 20 to 60 C base unit and basic control panel Ambient 1 around base unit storage and shipping temperature 40 to 90 C ambient Humidity up to 90 non condensing Polu...

Page 29: ...specify an MM200 relay is provided in the following order code figure Figure 19 MM200 order codes 1 6 1 Example of an MM200 order code MM200 BXL1S MM200 with basic control panel 24 V DC power supply...

Page 30: ...26 MM200 MOTOR MANAGEMENT SYSTEM QUICKSTART GUIDE MM200 ORDER CODES QUICKSTART GUIDE...

Page 31: ...T GUIDE i 1 Index Index A Acceleration timer 20 C Current unbalance 20 G Ground fault protection 20 L Load increase 20 M Mechanical jam 20 O Output relays 22 Overview 1 S specifications 20 21 22 T The...

Page 32: ...i 2 MM200 MOTOR MANAGEMENT SYSTEM QUICKSTART GUIDE INDEX...

Page 33: ...Digital Energy Multilin SUMMARYOFCERTIFICATION...

Page 34: ...MM200 MOTOR MANAGEMENT SYSTEM QUICKSTART GUIDE...

Reviews: