Chapter 3: Using the Web Interface
260
Send Sensor Report
You may set the BCM2 so that it automatically reports the latest readings
or states of one or multiple sensors by sending a message or email or
simply recording the report in a log. These sensors can be either internal
or environmental sensors as listed below.
•
Inlet sensors, including RMS current, RMS voltage, active power,
apparent power, power factor and active energy.
•
Outlet sensors, including RMS current, RMS voltage, active power,
apparent power, power factor, active energy and outlet state (for
outlet-switching capable PDUs only).
•
Overcurrent protector sensors, including RMS current and tripping
state.
•
Peripheral device sensors, which can be any Raritan environmental
sensor packages connected to the BCM2, such as temperature or
humidity sensors.
An example of this action is available in the section titled
Send Sensor
Report Example
(on page 272).
Operation:
1.
Choose Device Settings > Event Rules >
.
2.
Select "Send sensor report" from the Action list.
3.
In the Destination Actions section, select the method(s) to report
sensor readings or states. The number of available methods varies,
depending on how many messaging actions have been created.
The messaging action types include:
Log event message
Syslog message
Send email
Send SMS message
a.
If no messaging actions are available, create them now. See
Available Actions
(on page 250).
b.
To select any methods, select them one by one in the Available
field.
To add all available methods, simply click Select All.
c.
To delete any methods, click a method's
in the Selected
field.
To remove all methods, simply click Deselect All.
4.
In the Available Sensors field, select the desired target's sensor.
Содержание PMC-1000
Страница 3: ...BCM2 Series Power Meter Xerus Firmware v3 4 0 User Guide...
Страница 23: ...Chapter 1 Installation and Initial Configuration 11 Panel Wiring Example...
Страница 54: ...Chapter 1 Installation and Initial Configuration 42 Branch Circuit Details...
Страница 76: ...Chapter 2 Connecting External Equipment Optional 64...
Страница 123: ...Chapter 3 Using the Web Interface 111...
Страница 558: ...Appendix D RADIUS Configuration Illustration 546 Note If your BCM2 uses PAP then select PAP...
Страница 559: ...Appendix D RADIUS Configuration Illustration 547 10 Select Standard to the left of the dialog and then click Add...
Страница 560: ...Appendix D RADIUS Configuration Illustration 548 11 Select Filter Id from the list of attributes and click Add...
Страница 563: ...Appendix D RADIUS Configuration Illustration 551 14 The new attribute is added Click OK...
Страница 564: ...Appendix D RADIUS Configuration Illustration 552 15 Click Next to continue...
Страница 594: ...Appendix E Additional BCM2 Information 582...
Страница 612: ......