Chapter 3: Using the Web Interface
253
Action
Function
Syslog message
Makes the BCM2 automatically forward event
messages to the specified syslog server. See
Syslog Message
(on page 268).
4.
Enter the information as needed and click Create.
5.
Then you can assign the newly-created action to an event rule or
schedule it. See
Event Rules and Actions
(on page 230).
Alarm
The Alarm is an action that requires users to acknowledge an alert. This
helps ensure that the user is aware of the alert.
If the Alarm action has been included in a specific event rule and no one
acknowledges that alert after it occurs, the BCM2 resends or
regenerates an alert notification regularly until the alert is
acknowledged or the maximum number of alert notifications is sent.
For information on acknowledging an alert, see Dashboard.
Operation:
1.
Choose Device Settings > Event Rules >
.
2.
Select Alarm from the Action list.
3.
In the Alarm Notifications list box, specify one or multiple ways to
issue the alert notifications. Available methods vary, depending on
how many notification-based actions have been created.
Notification-based action types include:
External beeper
Syslog message
Send email
Send SMS message
Internal beeper
If no appropriate actions are available, create them first.
a.
To select any methods, select them one by one in the Available
field.
To add all available methods, simply click Select All.
b.
To delete any methods, click a method's
in the Selected
field.
To remove all methods, simply click Deselect All.
4.
To enable the notification-resending feature, select the "Enable
Re-scheduling of Alarm Notifications" checkbox.
Содержание PMC-1000
Страница 3: ...BCM2 Series Power Meter Xerus Firmware v3 4 0 User Guide...
Страница 23: ...Chapter 1 Installation and Initial Configuration 11 Panel Wiring Example...
Страница 54: ...Chapter 1 Installation and Initial Configuration 42 Branch Circuit Details...
Страница 76: ...Chapter 2 Connecting External Equipment Optional 64...
Страница 123: ...Chapter 3 Using the Web Interface 111...
Страница 558: ...Appendix D RADIUS Configuration Illustration 546 Note If your BCM2 uses PAP then select PAP...
Страница 559: ...Appendix D RADIUS Configuration Illustration 547 10 Select Standard to the left of the dialog and then click Add...
Страница 560: ...Appendix D RADIUS Configuration Illustration 548 11 Select Filter Id from the list of attributes and click Add...
Страница 563: ...Appendix D RADIUS Configuration Illustration 551 14 The new attribute is added Click OK...
Страница 564: ...Appendix D RADIUS Configuration Illustration 552 15 Click Next to continue...
Страница 594: ...Appendix E Additional BCM2 Information 582...
Страница 612: ......