Goodrive350-19 series VFD Function parameter list
- 373 -
Function
code
Name
Description
Default
value
Modify
P92.04
P90.16
P90.16+2Hz
P92.05
Torque
current %
Output
frequency
Relay
output
Normal
Alarm A-OL
P92.04 setting range: 0.0
–150.0% (relative to the
motor rated torque in closed-loop state; relative to
the motor rated current in open-loop state; 0
indicates disabling)
P92.05 setting range: 0.0
–5.0s
P92.06
Brake detection
reminding interval
When P92.06>0, the brake detection reminding
function is enabled, if the accumulative running
time of the VFD is equal to or greater than P92.06,
the signal indicator is controlled through relay
output signal or braking detection is reminded
through the buzzer. The reminding hold time is
specified by P92.07. After the time elapsed,
reminding is not performed until re-power on.
P92.06 setting range: 0.0
–1000.0h
P92.07 setting range: 0
–100min
0.0
◎
P92.07
Brake detection
reminding hold
time
5
○
P92.08
Brake detection
torque setting
In open-loop control: Set a fixed torque and
frequency and run the VFD. Through visual
inspection, if the brake is not opened within the
detection time, braking is normal. Otherwise,
braking is abnormal.
In closed-loop control: When the braking force
detection terminal enabling signal is valid, the VFD
keeps the brake closed, if a running command is
150.0%
○
P92.09
Brake detection
frequency setting
5.00Hz
○
P92.10
Brake detection
time setting
5.0s
○
P92.11
Brake detection
500
○