Goodrive350-19 series VFD Function parameter list
- 336 -
Function
code
Name
Description
Default
value
Modify
Bits7
–15: Reserved
P24.18
Encoder pulse
filter width
0
–63
The filtering time is P24
.18×0.25 μs. The value 0
or 1 indicates 0.25 μs.
2
○
P24.19
Pulse reference
filter width
0
–63
The filtering time is P24.19
×0.25 μs. The value 0
or 1 indicates 0.25 μs.
10
○
P24.20
Pulse number of
pulse reference
0
–65535
1024
◎
P24.21
Enable angle
compensation of
synchronous
motor
0
–1
0
○
P24.22
Switch-over
frequency
threshold of
speed
measurement
mode
0
–630.00Hz
1.00Hz
○
P24.23
Angle
compensation
coefficient
-200.0
–200.0%
100.0%
○
P24.24
Motor pole pair
number in initial
pole angle
autotuning
0
–128
2
◎
7.2.25 P25 Extension I/O card input functions
Function
code
Name
Description
Default
value
Modify
P25.01
S5 terminal
Same as P05 group
0
◎