Goodrive350-19 series VFD Function parameter list
- 323 -
Function
code
Name
Description
Default
value
Modify
positioning only)
Bit3: P21.17 digital setting mode
0: Incremental
1: Position type (do not support continuous mode)
Bit4: Home searching mode
0: Search for the home just once
1: Search for the home during each run
Bit5: Home calibration mode
0: Calibrate in real time
1: Single calibration
Bit6: Positioning completion signal selection
0: Valid during the time set by P21.25 (Hold time of
positioning completion signal)
1: Always valid
Bit7: Initial positioning selection (for cyclic
positioning by terminals)
0: Invalid (do not rotate)
1: Valid
Bit8: Positioning enable signal selection (for cyclic
positioning by terminals only; positioning function
is always enabled for automatic cyclic positioning)
0: Pulse signal
1: Level signal
Bit9: Position source
0: P21.17 setting
1: PROFIBUS/CANopen setting
Bit10: indicates whether to save the encoder pulse
counting value at power outage
0: Not save
1: Save