Goodrive350-19 series VFD Function parameter list
- 312 -
Function
code
Name
Description
Default
value
Modify
4: Low voltage protection alarm (A-LvP)
5: Overload protection alarm (A-OL)
6: Brake failure alarm (A-bS)
7: Brake feedback alarm (A-FA)
8: Loose rope protection alarm (A-SL)
9: PT100 overtemperature alarm (A-Ot1)
10: PT1000 overtemperature alarm (A-Ot2)
11: PT100 disconnection alarm (A-Pt1)
12: PT1000 disconnection alarm (A-Pt2)
13: PTC overtemperature alarm (A-Ptc)
P19.11
Torque for load
detection
0.0%
–150.0% (of the motor rated torque)
0.0%
●
P19.12
Brake detection
reminding interval
0.0
–1000.0h
0.0
●
P19.13
Present step of
graded multi-step
speed
0
–6
0
●
P19.14
Zero-point
position status
0
–2
0: VFD in running, with zero-point position input
1: VFD stopped, with zero-point position signal
input,
zero-point
position
delay
reached
(zero-point position valid)
2: In the condition of status 1, running command
valid when running command given and zero-point
position left (no zero-point position signal input)
0
●
P19.15 Measured height 0.00
–655.35m
(Hook lowering distance using the upward limit
position as the reference point)
0.00
●
P19.16 MSB of measured
height
0
–65535
0
●
P19.17 LSB of measured
height
0
–65535
0
●