Goodrive350-19 series VFD Operating
- 157 -
Setting
Function
Description
10
AI1 input value
0
–10V/0–20mA
11
AI2 input value
-10V
–10V
12
AI3 input value
0
–10V/0–20mA
13
Input value of high-speed
pulse HDIA
0.00
–50.00kHz
14
Set value 1 of MODBUS
communication
-1000
–1000, 1000 corresponds to 100.0%
15
Set value 2 of MODBUS
communication
-1000
–1000, 1000 corresponds to 100.0%
16
Set value 1 of
PROFIBUS/CANopen
communication
-1000
–1000, 1000 corresponds to 100.0%
17
Set value 2 of
PROFIBUS/CANopen
communication
-1000
–1000, 1000 corresponds to 100.0%
18
Ethernet communication set
value 1
-1000
–1000, 1000 corresponds to 100.0%
19
Ethernet communication set
value 2
-1000
–1000, 1000 corresponds to 100.0%
20
High-speed pulse HDIB input
value
0.00
–50.00kHz
21
Reserved variable
22
Torque current (bipolar, 100%
corresponds to 10V)
0
–Two times of rated current of motor
23
Exciting current (100%
corresponds to 10V)
0
–One times of rated current of motor
24
Set frequency (bipolar)
0
–Max. output frequency
25
Ramps reference frequency
0
–Max. output frequency