Goodrive350-19 series VFD Function parameter list
- 348 -
Function
code
Name
Description
Default
value
Modify
P29.25
Identification
current of
synchronous
motor 3
(Reserved)
0%
–
50% (of the motor rated current)
10%
●
P29.26
Overload
protection
selection of motor
3
0: Disable protection
1: Enable protection for common motors (with
low-speed compensation)
2: Enable protection for variable-frequency motors
(without low-speed compensation)
2
◎
P29.27
Overload
protection
coefficient of
motor 3
20.0%
–120.0%
100.0%
○
P29.28
Power display
correction
coefficient of
motor 3
0.00
–3.00
1.00
○
P29.29
Parameter display
selection of motor
3
0: Display by motor type
1: Display all
0
○
P29.30
System inertia of
motor 3
0
–
30.000kgm2
0.000
○
7.2.29 P90 Hoisting functions
Function
code
Name
Description
Default
value
Modify
P90.00
Hoisting function
macro setting
0
–12
0: Common application mode
1: Lifting mode 1 (in open-loop vector control)
2: Lifting mode 2 (in closed-loop vector control)
3: Horizontal moving mode (in space voltage
vector control)
4: Tower crane rotating mode
5: Conical motor application mode
6: User-defined function macro 1
0
◎