Goodrive350-19 series VFD Function parameter list
- 221 -
Function
code
Name
Description
Default
value
Modify
above)
6: Set via multi-step torque (the same as above)
7: Set via MODBUS communication (the same as
above)
8: Set via PROFIBUS/CANopen/DeviceNet
communication (the same as above)
9: Set via Ethernet communication (the same as
above)
10: Set via pulse frequency HDIB (the same as
above)
11: Set via EtherCat/Profinet communication
12: Set via PLC
P03.12
Torque set by
keypad
-300.0%
–300.0% (rated motor current)
20.0%
○
P03.13
Torque reference
filter time
0.000
–10.000s
0.010s
○
P03.14
Source of upper
limit frequency
setup of forward
rotation in torque
control
0: Keypad (P03.16)
1: AI1 (100% corresponds to max. frequency)
2: AI2 (the same as above)
3: AI3 (the same as above)
4: Pulse frequency HDIA (the same as above)
5: Multi-step (the same as above)
6: MODBUS communication (the same as above)
7: PROFIBUS /CANopen/ DeviceNet
communication (the same as above)
8: Ethernet communication (the same as above)
9: Pulse frequency HDIB (the same as above)
10: EtherCat/Profinet communication
11: PLC
0
○