Goodrive350-19 series VFD Function parameter list
- 342 -
7.2.27 P28 Master/slave control functions
Function
code
Name
Description
Default
value
Modify
P28.00
Master/slave
mode selection
0: The master/slave control is invalid
1: This machine is a master
2: This machine is a slave
0
◎
P28.01
Master/slave
communication
data selection
0: CAN
1: Reserved
0
◎
P28.02
Master/slave
control mode
Ones: Master/slave running mode selection
0: Master/slave mode 0
(The master and slave adopt speed control and
maintains the power balance by droop control)
1: Master/slave mode 1
(The master and slave must be in the same type of
vector control mode. The master is speed control,
and the slave will be forced to be in the torque
control mode.
2: Master/slave mode 2
Start in the slave first speed mode (master/slave
mode 0) and then switch to torque mode at a
certain frequency point (master/slave mode 1)
3: Reserved
4: Closed-loop master/slave mode (master/slave
mode 4)
If the position synchronization mode is used, both
the master and slave must be installed with the
encoder. Both the master and slave adopt the
speed control and correct the speed by using the
position pulse deviation value.
5: Master/slave mode 5
Both the master and slave use closed-loop speed
control, and the slave use the speed loop output of
the master to perform power balancing.
Tens: Slave start command source selection
0x001
◎