Goodrive350-19 series VFD Function parameter list
- 245 -
Function
code
Name
Description
Default
value
Modify
P05.13
S1 terminal
switch-off delay
variation from switch-on to switch-off .
Si electrical level
Si valid
invalid
invalid
Switcn-on
delay
Switcn-off
delay
valid
Setting range: 0.000
–50.000s
Note:
After a virtual terminal is enabled, the state
of the terminal can be changed only in
communication
mode.
The
communication
address is 0x200A.
0.000s
○
P05.14
S2 terminal
switch-on delay
0.000s
○
P05.15
S2 terminal
switch-off delay
0.000s
○
P05.16
S3 terminal
switch-on delay
0.000s
○
P05.17
S3 terminal
switch-off delay
0.000s
○
P05.18
S4 terminal
switch-on delay
0.000s
○
P05.19
S4 terminal
switch-off delay
0.000s
○
P05.20
HDIA terminal
switch-on delay
0.000s
○
P05.21
HDIA terminal
switch-off delay
0.000s
○
P05.22
HDIB terminal
switch-on delay
0.000s
○
P05.23
HDIB terminal
switch-off delay
0.000s
○
P05.24
Lower limit value
of AI1
These function codes define the relation between
analog input voltage and corresponding set value
of analog input. When the analog input voltage
exceeds the range of max./min. input, the max.
input or min. input will be adopted during
calculation.
When analog input is current input, 0
–20mA
0.00V
○
P05.25
Corresponding
setting of lower
limit of AI1
0.0%
○
P05.26 Upper limit value
10.00V
○