Goodrive350-19 series VFD Commissioning
- 72 -
Start
Enable brake
control
Motor torque >
Torque
verification
reference?
Motor speed <
Slip speed limit?
Y
N
N
Brake system starts
checking
Torque reference
Brake slip speed limit
reference
Torque verification
pass
Torque slip pass
Torque verification pass
Torque slip pass
Brake system allows to
open the brake
Y
Torque verification
fault detection time
reached
Brake slip fault delay
reached
Reports brake slip
fault
Reports torque
verification fault
5.9.4 Commissioning parameters
Function
code
Name
Description
Default
P90.04
Enabling brake-oriented logic
0
–1
0: The brake is controlled by an
external controller.
1: The brake is controlled by the
VFD.
0
P90.05
Enabling forward torque for
reverse-running start/stop
0x00
–0x11
Ones place: indicates whether to
enable forward torque for
reverse-running start
0: Disable
(The reverse-running start direction
complies with the command.)
1: Enable
0x00