Goodrive350-19 series VFD Operating
- 134 -
Function
code
Name
Description
Default
value
P03.13
Torque reference
filter time
0.000
–10.000s
0.010s
P03.14
Source of upper
limit frequency
setup of forward
rotation in torque
control
0: Keypad (P03.16)
1: AI1 (100% corresponds to max. frequency)
2: AI2 (the same as above)
3: AI3 (the same as above)
4: Pulse frequency HDIA (the same as above)
5: Multi-step (the same as above)
6: MODBUS communication (the same as
above)
7: PROFIBUS /CANopen/ DeviceNet
communication (the same as above)
8: Ethernet communication (the same as above)
9: Pulse frequency HDIB (the same as above)
10: EtherCat/Profinet communication
11: PLC
12: Reserved
Note:
For the options 1-11, 100% is relative to
the max. frequency.
0
P03.15
Source of upper
limit frequency
setup of reverse
rotation in torque
control
0: Keypad (P03.17)
1: AI1 (100% corresponds to max. frequency)
2: AI2 (the same as above)
3: AI3 (the same as above)
4: Pulse frequency HDIA (the same as above)
5: Multi-step (the same as above)
6: MODBUS communication (the same as
above)
7: PROFIBUS /CANopen/ DeviceNet
communication (the same as above)
0