Goodrive350-19 series VFD Function parameter list
- 329 -
Function
code
Name
Description
Default
value
Modify
Tens: Analog port selection
0: Invalid
1: AI1
2: AI2
3: AI3
P22.19
Analog filter time
of rigid tapping
0.0ms
–1000.0ms
1.0ms
○
P22.20
Max. frequency of
rigid tapping
0.00
–400.00Hz
50.00Hz
○
P22.21
Corresponding
frequency of
analog zero drift
of rigid tapping
0.00
–10.00Hz
0.00Hz
○
P22.22
Pulse reference
speed measuring
method
0
–2
0: Measured by the main control board
1: Measured by the PG card
2: Hybrid speed measuring
0
○
P22.23
Reserved
0
–65535
0
P22.24
Encoder counting
clearing setting
0
–65535
0
○
7.2.23 P23 Vector control of motor 2
Function
code
Name
Description
Default
value
Modify
P23.00
Speed loop
proportional gain
1
P23.00
–P23.05 fit for vector control mode only.
Below switch-over frequency 1 (P23.02), the
speed loop PI parameters are P23.00 and P23.01.
Above switch-over frequency 2 (P23.05), the
speed loop PI parameters are P23.03 and P23.04;
20.0
○
P23.01
Speed loop
integral time 1
0.200s
○