Goodrive350-19 series VFD Commissioning
- 47 -
5.3 Commissioning horizontal moving
5.3.1 Wiring
(+)
PB
GD350-19 VFD
R
S
T
R
S
T
M
3~
U
V
W
PE
S1
S2
S3
S4
HDIA
HDIB
S5
S6
COM
VFD fault
output
Brake
output
RO1A
RO1B
RO1C
RO2A
RO2B
RO2C
Y1
CME
HDO
COM
CME
+24V
Forward running
Reverse running
Multi-step speed
setting terminal 1
Multi-step speed
setting terminal 2
Fault reset
Coasting to stop
Braking resistor
S8
S7
PW
+24V
Figure 5.3 Wiring for horizontal moving
Note:
If the wiring is performed according to Figure 5.3, most VFD parameters need no adjustment. If
the onsite function terminals are inconsistent with the terminals shown in the figure, adjust the input
and output terminal functions according to the actual wiring after selecting the horizontal moving
application macro.
5.3.2 Commissioning procedure
1. Check the wiring and ensure the wiring is proper.
2. Set P00.18=1.
3. Set motor nameplate parameters in P02.
4. Set P90.00=3 to select the horizontal moving function macro.
5. Perform low-speed trial running.