Goodrive350-19 series VFD Operating
- 106 -
No.
Item
Description
DATA
ENT
Entry key
Press it to enter menus in cascading mode or
confirm the setting of a parameter.
Up
Press it to increase data or move upward.
Down
Press it to decrease data or move downward.
SHIFT
Right-shifting
Press it to select display parameters
rightward in the interface for the device in
stopped or running state or to select digits to
change during parameter setting.
RUN
Run
Press it to run the device when using the
keypad for control.
STOP
RST
Stop/Reset
Press it to stop the device that is running.
The function of this key is restricted by
P07.05. In fault alarm state, this key can be
used for reset in any control modes.
QUICK
JOG
Multifunctional
shortcut key
The function is determined by P07.04.
6.3 Keypad display
The display state of GD350-19 series keypad is divided into stop parameter display state, running
parameter display state and fault alarm display state.
6.3.1 Displaying fault information
After detecting a fault signal, the VFD enters the fault alarm state immediately, the fault code blinks on
the keypad, and the TRIP indicator is on. You can perform fault reset by using the STOP/RST key,
control terminals, or communication commands.
If the fault still persists, the fault code is continuously displayed.
6.3.2 Editing function codes
You can press the PRG/ESC key to enter the editing mode in stopped, running, or fault alarm state (if
a user password is used, see the description of P07.00). The editing mode contains two levels of
menus in the following sequence: Function code group or function code number
→
Function
parameter. You can press the DATA/ENT key to enter the function parameter display interface. On the
function parameter display interface, you can press the DATA/ENT key to save parameter settings or
press the PRG/ESC key to exit the parameter display interface.