Goodrive350-19 series VFD Function parameter list
- 350 -
Function
code
Name
Description
Default
value
Modify
macros
2: Switch from motor 1 to motor 3
3: Switch from the master to the slave
4: Switch from the slave to the master
5: Switch to SVC1 control (open-loop vector
control mode 1)
P90.04
Enabling
brake-oriented
logic
0
–1
0: The brake is controlled by an external controller.
1: The brake is controlled by the VFD.
0
◎
P90.05
Enabling forward
torque for
reverse-running
start/stop
0x00
–0x11
Ones place: indicates whether to enable forward
torque for reverse-running start
0: Disable
(The reverse-running start direction complies with
the command.)
1: Enable
(The reverse-running start direction is always the
forward-running direction.)
Tens place: indicates whether to enable forward
torque for reverse-running stop
0: Disable
(The reverse-running stop direction complies with
the command.)
1: Enable
(The reverse-running stop direction is always the
forward-running direction.)
0x00
◎
Run
cmd
RVS
Run
cmd
RVS
Output
frequency
Disable for RVS start
Enable
Output
frequency