Goodrive350-19 series VFD Function parameter list
- 244 -
Function
code
Name
Description
Default
value
Modify
FWD
REV
COM
Sln
SB2
SB1
SB3
Sln
FWD
REV
Running
direction
ON
OFF→ON
ON
Forward
OFF
Forward
ON
ON
OFF→ON
Reverse
OFF
Reverse
ON→OFF
Decelerate to
stop
Sln: 3-wire control/Sin, FWD: Forward running,
REV: Reverse running
Note:
For dual-line running mode,
when
FWD/REV terminal is valid, if the VFD stops due to
stop command given by other sources, it will not
run again after the stop command disappears
even if the control terminals FWD/REV are still
valid. To make the VFD run again, you need to
trigger FWD/REV again, for example, PLC
single-cycle stop, fixed-length stop, and valid
STOP/RST stop during terminal control. (See
P07.04.)
P05.12
S1 terminal
switch-on delay
These function codes define corresponding delay
of the programmable input terminals during level
0.000s
○