Goodrive350-19 series VFD Function parameter list
- 313 -
Function
code
Name
Description
Default
value
Modify
P19.18
PT100 present
temperature
-50.0
–150.0°C
0.0
°
C
●
P19.19
PT100 present
digital
0
–4096
0
●
P19.20
PT1000 present
temperature
-50.0
–150.0°C
0.0
°
C
●
P19.21
PT1000 present
digital
0
–4096
0
●
P19.22 Brake slip speed 0.00Hz
–10.00Hz
0.00Hz
●
P19.23
Brake slip pulse
value
0
–65535
0
●
P19.24 Light load speed
boost status
0
–3
0: Normal
1: FWD light load speed boost
2: RVS light load speed boost
3: Constant-power speed boost
0
●
P19.25 Status of derating
frequency with
voltage
0
–1
0: Normal
1: Derating frequency with voltage
0
●
P19.26
Torque value for
stable rope
loosening
0.0%
–150.0% (of the motor rated torque)
0.0%
●
P19.27
Present load
torque change
ratio of stable
lifting
0.0
–100.0%/s
0.0%
●
P19.28
Stable lifting
status
0
–1
0: Normal
1: In stable state
0
●
P19.29 Current imbalance 0.0
–6553.5
0.0
●