Goodrive350-19 series VFD Function parameter list
- 370 -
Function
code
Name
Description
Default
value
Modify
corresponding to
f1 frequency point
P91.38 setting range: P91.40
–P00.03 (Max.
output frequency)
P91.40 setting range: P91.42
– P91.38
P91.42 setting range: P91.44
– P91.40
P91.44 setting range: P91.46
– P91.42
P91.46 setting range: 0.00Hz
–P91.44
P91.39, P91.41, P91.43, P91.47 setting range:
0.0%
–100.0%
Note:
The duty ratio and frequency segmenting
are used for regulation.
P91.42 f2 frequency point
20.00Hz
○
P91.43
Duty cycle
corresponding to
f2 frequency point
40.0%
○
P91.44 f3 frequency point
10.00Hz
○
P91.45
Duty cycle
corresponding to
f3 frequency point
20.0%
○
P91.46 f4 frequency point
0.00Hz
○
P91.47
Duty cycle
corresponding to
f4 frequency point
0.0%
○
P91.48
HDO carrier
frequency
0.5
–10.0kHz
1.0kHz
○
P91.49
HDO closing
delay during stop
0
–
100.0s
5.0s
○
P91.50
Pre torque input
signal source
0
–4
0: Invalid
1: AI1
2: AI2
3: Modbus
4: Internally given
0
○
P91.51 Pre torque offset In closed-loop mode:
Setting pre torque is to output the torque
corresponding to load weight in advance so as to
reduce the start impact and prevent reserve
driving or slip during start.
Setting P91.51 is to eliminate the impact of
mechanical counterweight for lifting; pre torque
compensation is directly performed if there is no
mechanical counterweight.
Pre
torque
compensation
quantity
=
K*(P91.50
–P91.51), in which K= P91.52 when the
0.0%
○
P91.52
Drive-side gain
1.000
○
P91.53 Braking-side gain
1.000
○