Goodrive350-19 series VFD Operating
- 165 -
Setting
Function
Description
41
Maintain power
consumption quantity
When this command is valid, current operation of the
VFD will not impact the power consumption quantity.
42
Source of upper torque limit
switches to keypad
When this command is valid, the upper limit of the torque
will be set by keypad.
43
Position reference point
input
Valid only for S1, S2, and S3.
44
Prohibit spindle orientation The spindle positioning function is invalid.
45
Spindle zeroing/local
positioning zeroing
Used to trigger spindle positioning.
46
Spindle zero-point position
selection 1
Terminal-selected spindle zero-point position 1.
47
Spindle zero-point position
selection 2
Terminal-selected spindle zero-point position 2.
48
Spindle scale-division
selection 1
Terminal-selected spindle scale-division 1.
49
Spindle scale-division
selection 2
Terminal-selected spindle scale-division 2.
50
Spindle scale-division
selection 3
Terminal-selected spindle scale-division 3.
51
Position/speed control
switching terminal
Used to switch position control and speed control.
52
Pulse input inhibition
When the terminal is valid, pulse input is invalid.
53
Clear position deviation
Used to clear the input deviation of the position loop.
54
Position proportional gain
switchover
Used to switch position proportional gains.
55
Enable cyclic digital
positioning
When the digital positioning mode is valid, the cyclic
positioning function can be enabled.
56
Emergency stop
When this command is valid, the motor decelerate to